Inta 750mm Insulated Hoses w/ Elbow 1
Sale

Inta 750mm Insulated Hoses w/ Elbow 1" Female Swivel x 28mm - HPHOSE750B

£129.99 In Stock Direct from Supplier Order Get in touch for pricing or lead times!
Contact our sales team for pricing or availability
  • Description
  • Reviews

In systems where every watt counts, Inta’s Pre insulated hoses have been designed for external use to prevent heat losses and to help maintain the COP and SCOP of the system, preventing losses of energy, contributing to an efficient system and preventing higher costs to run than expected.

The water resistant finish prevents the insulation from absorbing water and moisture that could result in an unintended outcome of the insulation becoming a conductor for heat loss.

- Pre-insulated to reduce system heat loss preserving system efficiency
- Available with 1″ female x 28mm or 1 1/4″ Female x 35mm connections
- Supplied in pairs to suit the flow and return of your heat pump
- Designed to connect directly to the heat pump
- Available with a straight or bent heat pump connection to suit a variety of units and installations.

Inta 750mm Pre-Insulated Hoses w/ Elbow 1" Female Swivel (Union) x 28mm (Compression) 

HOSE
Max inlet pressure (static): 10 Bar
Max inlet temperature: 90°C
Medium: water, water+glycol up to 50%

Insulation
Wall thickness: 19mm +0 / -3mm
Material: treated closed cell polyethylene
Temperature range: -45°C to 105°C
Thermal conductivity: λ = 0.035 W/mk at 40°C
Water vapour diffusion resistance: μ ≥ 39,300

Additional piece of insulation provided to insulate the connections
Full range of ASHP control valves including magnetic filters, antifreeze valves, balancing valves etc available.

The Primary Pro insulation is water and UV resistant making it suitable for all weather conditions. Check joints on annual service and re-seal if required using Bond & Seal
Check coating and re-coat if required on annual service.

Building regulations Part L states that all external pipework on an Air Source Heat Pump System must be fully insulated to reduce heat loss and maintain system efficiency.

It’s essential that all joints are bonded and sealed correctly to prevent any capillary traction occurring. The surface finish must be re-treated, the joints and seals inspected and resealed if necessary using Primary Pro Bond / Seal during an annual inspection to maintain the product performance.


THE INSULATION IS STRICTLY FOR EXTERNAL USE ONLY!

 